Wide-neck bifurcation aneurysms of the middle cerebral artery and basilar apex treated by endovascular techniques: a multicentre, core lab adjudicated study evaluating safety and durability of occlusion (BRANCH).
Abstract
BACKGROUND AND PURPOSE:
BRANCH (wide-neck bifurcation aneurysms of the middle cerebral artery and basilar apex treated by endovascular techniques) is a multicentre, retrospective study comparing core lab evaluation of angiographic outcomes with self-reported outcomes.
MATERIALS AND METHODS:
Consecutive patients were enrolled from 10 US centres, aged between 18 and 85 with unruptured wide-neck middle cerebral artery (MCA) or basilar apex aneurysms treated endovascularly. Patient demographics, aneurysm morphology, procedural information, mortality and morbidity data and core lab and self-reported modified Raymond Roy (RR) outcomes were obtained.
RESULTS:
115 patients met inclusion criteria. Intervention-related mortality and significant morbidity rates were 1.7% (2/115) and 5.8% (6/103) respectively. Core lab adjudicated RR1 and 2 occlusion rates at follow-up were 30.6% and 32.4% respectively. The retreatment rate within the follow-up window was 10/115 (8.7%) and in stent stenosis at follow-up was 5/63 (7.9%). Self-reporting shows a statistically significant direction to angiographic RR one outcomes at follow-up compared with core lab evaluation, with OR 1.75 (95% CI 1.08 to 2.83).
CONCLUSION:
Endovascular treatment of wide-neck MCA and basilar apex aneurysms resulted in a core lab adjudicated RR1 occlusion rate of 30.6%. Self-reported results at follow-up favour better angiographic outcomes, with OR 1.75 (95% CI 1.08 to 2.83). These data demonstrate the need for novel endovascular devices specifically designed to treat complex intracranial aneurysms, as well as the importance of core lab adjudication in assessing outcomes in such a trial.
© Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2019. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
KEYWORDS:
aneurysm; balloon; coil; intervention; stent
- PMID:
- 29858397
- DOI:
- 10.1136/neurintsurg-2018-013771